Introduction and company overview
Welcome to the RTT Finishing Solutions Academy. Thanks for joining today’s webinar on spray booth sizing and selection. I’m John Owed, Director of Sales at RTT Finishing Solutions.
If you’ve visited our facility, thank you. If you haven’t, we’d welcome the chance to host you. Our 150,000 sq. ft. corporate headquarters and manufacturing facility is in Rockwall, Texas, just east of Dallas.
We have three main business segments:
- Core catalog equipment: standard liquid and powder booths, batch ovens and other equipment that supports the finishing process and the environment around it.
- Engineered Projects (EP): larger, more complex spray booths, parts washers, elevated ovens and process ovens, typically for moving lines. We engineer these to meet specific customer needs.
- RP Filtration products: we acquired the RP brand in 2017 and integrated it into our manufacturing facility. We manufacture slit-and-expanded paper filters with a polyester backing. We’re the only spray booth manufacturer that also makes its own filtration products, which is why we can offer a five-year warranty on our spray booths when our filters are used.
Today we’re focusing mostly on liquid booths, so we’ll talk mainly about core catalog equipment, with some larger booths as examples.
We’ll cover:
- Why you need a spray booth
- The major components of a spray booth
- Booth types and OSHA and NFPA airflow requirements
- The two major booth classifications, crossdraft and downdraft, and how airflow is calculated for each
- How to size a booth for a specific part
- Upgrades that improve booth performance
Why you need a spray booth
A spray booth contains and evacuates the atomized particles and vapors created during spray application. When you atomize paint, you create solids and vapors. The booth captures and contains them.
It also keeps overspray from migrating through the facility and causing contamination. If people outside the spray area complain about odors, the booth may not be operating properly or hasn’t been optimized for the application.
A spray booth also provides a clean environment to paint in and minimizes contamination of the coated product. This automotive example is an enclosed booth with filtered intake and exhaust air, which is what you need to achieve a Class A finish.
A spray booth also prevents a combustible mix of flammable vapors and air from forming, where a static spark could cause ignition.
Most importantly, OSHA and NFPA require one, for all the reasons above, to create a safe environment.
Spray booth components
A spray booth consists of:
- The work area: the compartment where spraying takes place.
- The exhaust chamber: the exhaust filters mount on the face of the filter chamber and trap paint particles.
- The exhaust fan: behind the filters, ducted outside the building to remove harmful vapors.
Booths can be open-face or enclosed. An open-face booth can pull dirt and debris from the surrounding area into the finish. If you’re painting structural steel and the main goal is getting primer on to prevent rust, a little dust doesn’t matter, so the cost of an enclosed booth with filtered air may not be justified. For automotive parts that need a Class A finish, you want an enclosed booth with filtered intake air, so clean air flows through the booth.
Filter chamber: this illustration shows sixteen 20" x 20" filter pads. RTT booths now ship standard with blanket media instead. A booth this size uses two large blankets instead of 16 individual pads. The blankets lock in place with our FilterLoc Track system, so filter changes are faster and you get a much better seal, which prevents overspray bypass.
Lighting: the number of light fixtures depends on booth size. All of our booths are designed to provide [confirm foot-candle rating]. All RTT booths ship with true LED lights. They give you better color rendering and use about 50% less energy.
Fire baffle: across the front of the booth is a vertical metal strip, about 4–6" high. Code requires it on all booths. If there’s a thermal incident in the booth, it helps keep flames from rolling out and gives the fire suppression system a chance to put out the fire.
Manometer: an important and often overlooked component. All booths are required to have a visual indicator that shows when the filters are loaded, and a manometer is the simplest and most cost-effective option. One is provided with every booth, but we often see them not connected. That can mean a $5,000 OSHA fine if you’re inspected.
The manometer measures the pressure differential between the booth’s working chamber and the filter chamber, which indicates filter loading. Most booths start at about 0.05" of static pressure when the booth is new and the filters are clean. Mark that starting point with the green arrow. When the reading reaches 0.5" of static pressure, it’s time to change the filters.
How often should filters be changed? That depends on many variables: how much paint is sprayed, how close operators are to the filters, and the type of paint. Some customers change filters once or twice a day on multiple shifts. Others change them once a month. Since we manufacture filters, we appreciate the customers who change them daily.
In the exhaust chamber, the filter media mounts at the face and the fan sits above it. Air is drawn through the filters and up and out the exhaust.
Crossdraft vs. downdraft booths
Spray booths are designated by the direction of airflow. There are two main types:
- Crossdraft: air moves horizontally. In this automotive booth, air enters through filter doors, is drawn across the vehicle and is exhausted.
- Downdraft: air moves predominantly vertically. Air enters from above and travels down. In this example, a pit runs down the center of the booth, covered with grating, with the filter media below it. Air is drawn through and exhausted.
OSHA and NFPA airflow requirements
OSHA and NFPA guide how much airflow a booth needs. I’m not an OSHA or NFPA expert, but we have people at RTT with more expertise who can help with detailed questions. You can also consult the official OSHA and NFPA documents for full details. Here are the highlights:
- OSHA 1910.107: airflow must be at least 100 linear feet per minute (fpm). For electrostatic applications, which have higher transfer efficiency and less overspray, airflow can be lower, but not less than 60 fpm.
- OSHA 1910.94, Table G-10: required airflow velocities range from 50 to 250 fpm at the booth opening. We’ll come back to this.
- OSHA 1910.94 also addresses the lower explosive limit (LEL): vapor concentration must stay below 25% of the LEL.
- NFPA 33, Chapter 7 (Ventilation), Section 7.2, Performance Requirements: booth ventilation must keep vapor concentration below 25% of the lower flammable limit (LFL).
LEL and LFL are essentially interchangeable. These are the guidelines for designing spray booths.
Crossdraft airflow formula
In a crossdraft booth, such as a simple industrial (IB) booth, airflow is horizontal. The formula is:
Booth width x booth height x 125 fpm = required CFM
Code requires 100 fpm, but we design our catalog booths for 125 fpm. That extends filter life and gives you margin if you add openings to the booth, such as conveyor openings.
Example: a 10 ft. wide x 10 ft. high booth has a 100 sq. ft. face. At 125 fpm, it needs a fan that pulls 12,500 CFM through the face opening.
The larger booth we looked at earlier is about 10 ft. high and 40 ft. long, four times bigger. It needs about 50,000 CFM, which is why it has two relatively large fans.
If you can use a narrower booth, such as the 10 x 10 at 12,500 CFM, the booth costs less, and you’re also exhausting less air. That matters because exhausted air has to be replaced. In a cold climate, you don’t want to pull cold air into the building, so less exhaust means energy savings. If a long part, such as structural steel, can fit in a narrower booth with more depth, operating costs go down.
Booth selection comes down to the part, the requirements, and your RTT regional sales manager helping you make the right recommendation for the customer.
Crossdraft booth variations
Crossdraft booths come in many shapes and sizes:
- Exhaust chambers: essentially a filter wall
- Benchtop booths
- IB booths, as shown earlier
- Enclosed crossdraft booths with filter doors: for cleaner finishes and less debris. Air enters through the filter doors and is drawn across the booth.
- Semi-crossdraft booths: solid doors, with filtered air entering through the top. Air is drawn down and then across the booth. Some customers like this design because they can add an air makeup unit later to upgrade the booth.
When an air makeup unit is dedicated to a booth, it becomes a pressurized booth. Pressurized booths let you control and adjust airflow as the filters load.
Crossdraft booths also work well with automated systems where a conveyor moves through the booth. This example is a manual push-pull conveyor: parts are loaded, moved into the booth and sprayed. You could also use an overhead conveyor or a floor-mounted chain conveyor.
Any openings in the side of the booth also draw air, and air always takes the path of least resistance. When designing or selling a booth, account for every opening. Here, a 1 ft. x 2 ft. opening adds 2 sq. ft., for a total of 104 sq. ft. On an engineered booth, we default to 100 fpm, or we can design for whatever airflow the installation warrants. At 100 fpm, this booth needs 10,400 CFM.
Keep in mind that higher airflow pulls more overspray. With a rotary atomizer and its softer spray pattern, you may not want high airflow. With electrostatic application, you can design the booth for 60 fpm. We can work with you on special applications. Another option is an upgraded control panel with a variable frequency drive (VFD) on the exhaust motor, so you can adjust airflow.
Because our catalog booths are designed for 125 fpm and the minimum is 100 fpm, you can buy a standard booth and cut conveyor openings on site. As long as the openings total less than 25% of the booth face, you’ll still be at 100 fpm. Standard booths with simple on-site modifications are pre-engineered and often the most cost-effective solution.
Large crossdraft examples
Crossdraft booths can be scaled up significantly. The booth on the left is 135 ft. wide x 50 ft. high x 193 ft. long. The customer coats sections of offshore oil platforms and needs room to move around them with scaffolding and lifts. They also blast and paint in this booth, so it has additional controls and interlocks beyond a typical booth. You can scale a booth as large as the process requires.
Another example is a crossdraft booth for locomotives. The challenge with crossdraft airflow is distance: will the overspray make it all the way to the filters? An automotive booth is typically 26 ft. deep, and the air movement carries overspray to the filters. Scale that up to a 100 ft. locomotive booth and it’s much harder. A crossdraft booth may still be chosen for footprint, budget or other reasons, but expect more overspray on the floor and more cleanup.
Downdraft booths and airflow formula
In a downdraft booth, airflow is predominantly vertical, from the top down. The industry standard for designing downdraft airflow is different from crossdraft. It focuses more on staying below 25% of the LEL or LFL, which means looking at the number of air changes.
Downdraft booths also typically coat larger parts, and the part occupies some of the booth volume. The formula is:
Booth width x booth length x 35 fpm (automotive) or 50 fpm (industrial, such as rail cars or trucks) = required CFM
Example: a 14 ft. x 26 ft. booth is 364 sq. ft.
- At 35 fpm (automotive): 12,740 CFM
- At 50 fpm (industrial): 18,200 CFM
We can use lower velocities because the part takes up much of the booth area, so the resulting airflow around the part is actually higher. Gravity also helps move overspray into the filter media. Those are the reasons downdraft booths are designed for lower airflow rates.
Downdraft configurations:
- Pit downdraft: a pit in the floor, covered with grating, with filter media below. Air is typically drawn out through a single exhaust stack. Pits can run down the center or along the walls, depending on the part. For a car hauler with a lot of open area, a center pit may work. For a large truck, which is essentially a large box, side pits are more effective because you don’t need to draw air underneath the vehicle.
- Side downdraft: a filtered plenum runs along the lower section of each side wall, creating downward airflow. This design typically has exhaust fans on each side, but it eliminates the need for a pit. Building a concrete pit and its connections can be expensive, so a side downdraft booth can be more cost-effective and deliver the same airflow results. Side downdraft booths are common in automotive repair shops. The filters are also easier to access, because you don’t have to remove floor grating.
Here’s a 130 ft. long side downdraft booth used to coat wind turbine towers and blades. Downdraft airflow gives access to all sides of the parts. This industrial booth was designed for 50 fpm. Because the part occupies about 50% or more of the space, airflow along the sides to the filter media is about 100 fpm. That’s why downdraft booths are designed for lower airflow: the part takes up so much space that the resulting airflow is higher.
Choosing crossdraft or downdraft
- Crossdraft booths typically require a lower capital investment. They range from small open-face booths to large enclosed booths. An open-face booth doesn’t filter incoming air, so it depends on whether you need a Class A finish or can accept some dust in the finish. For a car in a 26 ft. deep booth, crossdraft airflow pulls overspray efficiently to the filters. For a 100 ft. part like a locomotive, it won’t. The heavier particles will settle on the floor, which means more maintenance.
- Downdraft booths are typically better for larger, longer parts, using a side or pit design. Operators can also move more freely around the part than with a single filter wall at one end.
Spray technique: in a crossdraft booth, spray in the direction of airflow. For a car, start at the back and work forward, so the heavier paint layer goes over the overspray being drawn in that direction. In a downdraft booth, the air moves uniformly, so you can start anywhere on the part. You still want to work top-down, but under spray and overspray are less of a concern.
Our regional sales managers have a lot of experience helping make booth recommendations. It’s important to understand the part being coated and the finish required. Then we can help you make the most cost-effective recommendation to the end user.
Sizing a spray booth
Sizing is straightforward and depends on how much access you need.
- Around the part: allow 3–5 ft. on all sides so the operator can move freely. Consider 3 ft. the minimum. Holding a spray gun about 12" from the part uses up 3 ft. quickly, so 5 ft. is much more comfortable. Allow the same above the part, especially if you need to raise it.
- Filter distance: the farther the part is from the filter media, the better. Distance lets overspray disperse into the airflow and load the entire filter face evenly. Too close, and the filters face-load quickly. Allow a minimum of 18", ideally 3–5 ft.
Example: about a year ago, I saw an automated installation in a small booth, about 4 ft. x 4 ft. The customer was coating oil filters on a chain-on-edge line with two stationary guns. The filter media was about 4" behind the parts, so overspray loaded the filters directly behind the parts. The filters dripped and ran, and they had to be replaced about every hour. With at least 18" to 3 ft. of distance, the overspray would have dispersed across the entire filter face, and in that high-volume application, the filters could probably have lasted a day.
Other information needed to quote:
- Voltage and phase: so we can size the controls and fan motor correctly. 480V three-phase is most efficient, but not every site has it. It may be 240V single-phase. We need to know so we quote correctly and ship the right electrical controls.
- Ceiling height: so we can quote the right amount of exhaust ductwork, from the top of the booth to the roof deck. The stack typically extends 6 ft. above the roof, though that varies by state.
Air makeup units
An air makeup unit (AMU) is an accessory, and in some cases a requirement. It replaces the air the spray booth exhausts. NFPA 33, Chapter 7 (Ventilation), Section 7.3 requires that exhausted air be replaced.
A couple of months ago, I visited a customer with two large open-face booths for painting transport racking, so the finish wasn’t critical. The facility had a welding operation at one end and the spray booths at the other, with no makeup air. The booths drew welding fumes and dirt through the entire plant. The doors were also very difficult to open and close because of the negative pressure, which is a safety issue.
Our solution was a demand unit, an air makeup unit that supplies air to the building. It was interfaced with the booths: with one booth running, it ran at a third of capacity. With two booths running, it went to two-thirds. With the welding operation also running, it ran at full speed to replace all the exhausted air.
So an AMU can supply air directly to the building, through a supply plenum, or through room distribution that the booths draw from.
AMUs are available in vertical and horizontal configurations. These two pictures show horizontal units coupled directly to enclosed booths for a Class A finish. These are pressurized booths. A dedicated AMU lets you balance the booth and maintain that balance automatically as the filters load.
A dedicated AMU also lets you set up a spray/bake booth. Spray the part, then switch to cure mode, and the AMU increases heat output to accelerate curing.
AMUs are typically sized for a specific booth. For multiple booths, we can provide a higher-output demand unit. Depending on ceiling height and available space, an AMU can be mounted inside or outside the building.
Booth doors
Door options depend on the finish you need and your floor space:
- Filter doors
- Solid doors, when intake air enters from above
- Roll-up doors
- Bi-fold or tri-fold doors
- Doors at both ends for a pass-through booth
Pass-through booths are common for locomotives and for in-line batch processes, where the part moves through the booth during the finishing process.
Selection and sizing guide
Our Industrial Spray Booth Selection and Sizing Guide summarizes this presentation for smaller industrial and standard booths. It’s a brochure you can bring to customer visits. It includes:
- A booth overview, including the five-year warranty when RTT filters are used
- A selection chart of standard sizes and configurations. Standard booths are typically available for delivery in 10 days or less, and we can build custom booths in any shape and size.
- An illustration for walking the customer through sizing around the part
- The major booth components
- Booth supplies, including our three W Series filters. All booths ship with W Series 5100 blanket filters and the FilterLoc Track system, a channel around the exhaust chamber. The blanket media installs with the FilterLoc insertion tool. Booths are still available with 20" x 20" grids if specified. If not specified, they ship with blanket media.
- Intake filters for enclosed booths
- Accessories. All RTT booths ship powder-coated white, with true LED lights for better light rendering. The LED lights carry a five-year warranty.
- Control upgrades, such as touchscreen or more advanced controls, plus exhaust ductwork and door options
The back page is a request for quote (RFQ). Fill it in with the customer, including:
- Booth size, or the standard booth number
- The type and length of ductwork needed
- Ceiling height, so we can quote the right amount of exhaust duct
- Roof pitch or type, so we can include the right flashing for the roof penetration
- Electrical supply and phase, single or three-phase
- Filtration needs. Booths ship standard with W Series 5100 blankets.
- Any additional equipment or upgrades
Scan it or take a picture, send it to us, and we’ll prepare a quote.
Getting a quote
For a more detailed quote, go to [RTT website] and click the quote request link at the top. When you submit the RFQ, you’ll get an acknowledgment. Our inside sales team prepares quotes first in, first out, typically within 4–12 hours, so you’ll usually have it within a day. For more specific needs, contact your regional sales manager.
Our YouTube channel has all of our webinar recordings, plus videos on filter installation and our capabilities. We encourage you to visit it and direct customers there.
Additional support
Our regional sales managers cover the territories shown on the map. They can guide you through booth selection and complex projects, and join you on sales calls with end users. For literature or marketing support, contact [RTT marketing contact].
Thank you for joining us. This concludes our spray booth sizing and selection webinar.
Additional Resources
Spray Booth Recipe Setup
Presented by Bryan Willis
Proper Use and Measurement of a Manometer
Presented by Cayce Carr and Trey Peavy
Spray Booth Inspection for Compliance
Presented by John Owed
Monitor Part Temperature with Smartbatch
Presented by Bryan Willis
Download Reports from SmartTouch Control Panels
Presented by Bryan Willis
Successful Spray Booth Installations
Presented by Chris Schoch
Not Sure Which System You Need?
Get a system built around your application, with the right airflow, filtration, and fit for your facility.