EZ Classic Crossdraft Paint Booth
Optimize Your Finishing with a Proven Crossdraft Design
The EZ Classic Crossdraft Paint Booth delivers exceptional finishing results with industry-leading efficiency. Designed for automotive, industrial, and woodworking applications, this crossdraft system provides a reliable, cost-effective solution for all your finishing needs.
EZ Classic Crossdraft spray paint booths draw clean air through intake filters in the product entry doors. The air moves smoothly through the booth and exits through a high-efficiency exhaust filter system at the rear—ensuring a controlled environment for a flawless finish.
Benefits
RTT booths come equipped with premium filtration and airflow systems:
- W-Series RP Paint Arrestor filters – extended life and overspray control
- FilterLoc™ technology – tight seal and quick filter changes
- High-quality tubeaxial fans and motors
The RTT EZ Classic Crossdraft Paint Booth combines precision engineering, safety compliance, and streamlined performance to meet the demands of today’s high-quality finishing environments.
Built to Last. Easy to Maintain.
Every EZ Classic Crossdraft Paint Booth is designed with durability and user convenience in mind:
- 18-gauge prime-quality galvanized steel construction
- Precision-punched panels for easy nut-and-bolt assembly
- Field-adjustable slotted door hinges
- 36” personnel door with observation window and galvanized steel finish
- E-Light LED lighting
Technical Specifications
| Model Number | Interior Dimensions | Exterior Dimensions | Clear Door Opening | Qty. Lights | Airflow | Fan HP | Fan Dia. | |||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Width | Height | Length | Width | Height | Length | Width | Height | Qty | Type | |||||
| ECC-14-09-26-N-SB-S Non-Pressurized |
14' | 9' | 26' | 14′6.5"″ | 10' | 26'4" | 9′4" | 8'10.5" | 1 | Filtered | 10 | 12,600 SCFM | 3 HP | 30" |
| ECC-14-09-26-P-SB-S Pressurized |
14' | 9' | 26' | 14′6.5"″ | 10'6" | 26'4" | 9′4" | 8'10.5" | 1 | Solid | 10 | 12,600 SCFM | 3 HP | 30" |
| ECC-14-09-28-N-SB-S Non-Pressurized |
14' | 9' | 28' | 14′6.5"″ | 10'6" | 28'4" | 9′4" | 8'10.5" | 1 | Filtered | 10 | 12,600 SCFM | 3 HP | 30" |
| ECC-14-09-28-P-SB-S Pressurized |
14' | 9' | 28' | 14′6.5"″ | 10'6" | 28'4" | 9′4" | 8'10.5" | 1 | Solid | 10 | 12,600 SCFM | 3 HP | 30" |
| ECC-14-09-30-N-SB-S Non-Pressurized |
14' | 9' | 30' | 14′6.5"″ | 10'6" | 30'4" | 9′4" | 8'10.5" | 1 | Filtered | 10 | 12,600 SCFM | 3 HP | 30" |
| ECC-14-09-30-P-SB-S Pressurized |
14' | 9' | 30' | 14′6.5"″ | 10'6" | 30'4" | 9′4" | 8'10.5" | 1 | Solid | 10 | 12,600 SCFM | 3 HP | 30" |
Engineered for Your Needs
Choose from the following build options:
- Solid Back Paint Booths
- Drive-Through Booths
- Reverse Flow Designs
- Pressurized and Non-Pressurized Options
Whether you need a standard setup or a custom configuration, RTT Finishing Solutions has a paint booth solution tailored to your operational requirements.
Additional Paint Booth Options
- Durable powder coated white option available
- Air replacement units and intake chambers can be added
- 2-Stage filtration, 3-stage filtration, NESHAP filtration
- Conveyor/crane slot openings
- Control panel and other electrical components can be purchased separately
- Optional UL listed control panel with or without VFD
- Air solenoid valve interlocked with exhaust fan and spray equipment
- Height, width and depth can be custom designed to meet specific requirements
- Roll-up, bi-fold, or tri-fold doors
- Standard duty (10-guage support structure), heavy duty (W6x9 structure), or Xtreme duty (I-Beam construction with trusses)
- Solid back, drive through or reverse flow designs
- Pressurized or non-pressurized
- LED light fixtures
Bright, Efficient Lighting – Included
Each booth includes E-Light LED lighting, offering:
- Lower energy consumption
- True color rendering
- Extended life and reduced maintenance costs
LED housings are constructed of 22-gauge steel and powder-coated white. E-Lights are ETL listed for U.S. and Canada, rated Class 1 Division 2 (Groups A–D) and Class 2 Division 2 (Groups F & G).
RTT lighting is calculated and engineered using photometric software. E-Light fixtures are ETL listed and designed for proper use in spray booths. Because of this, our E-Light does not require a safety interlock saving on installation cost and additional maintenance.
Controls and Control Panels
RTT offers pre-wired motor starters, UL-listed control panels, VFD controls, and optional touchscreens to simplify operation, fan speed adjustment, and booth balancing. All panels feature a single-point connection for quick and easy installation. In addition, we offer monitoring systems that allow you to optimize the performance of your finishing system.
Filter Monitoring System
- Controls
UL Listed Standard
- Control Panels
Magnetic Motor Starter
- Control Panels
SmartTouch Touchscreen
- Control Panels
Variable Frequency Drive
- Control Panels
Paint Booth Filters
RTT offers a wide range of replacement paint booth filters — built from virgin paper materials and stocked for fast lead times. Whatever your application or filtration efficiency requirement, we have a solution ready to ship.
3200 Spra-Gard High Efficiency
- 3XXX-Series RP Paint Arrestors
3300 Spra-Gard High Efficiency
- 3XXX-Series RP Paint Arrestors
3400 Spra-Gard High Capacity High Efficiency
- 3XXX-Series RP Paint Arrestors
W-5000 High Efficiency
- W-Series RP Paint Arrestors
W-5100 Ultra Efficiency
- W-Series RP Paint Arrestors
W-5200 High Capacity Ultra Efficiency
- W-Series RP Paint Arrestors
Services
RTT provides end-to-end services tailored to every phase of your project, so you never have to look further than one trusted partner.
Custom Engineered Solutions
Ductwork
Installations
Maintenance
Product Training
Help and Support
Access the resources, documentation, and technical support information you need to keep your RTT equipment operating safely, efficiently, and at peak performance.
Product Literature
Extending the Life of Your Spray Booth
Frequently Asked Questions
When Should I Change the Filters on My Spray Booth?
When it comes to determining when to change your spray booth filters, first we must differentiate between intake filters and exhaust filters. Intake filters are located where the outside or shop air is introduced to the spray booth working environment. These filters work to ensure that the air introduced into the spray booth is free from debris, which can cause defects in your coatings. Exhaust filters are in separate locations, depending on the design and construction of your spray booth. The primary function of these filters is to capture overspray from the booth working environment and prevent harmful and hazardous particulates from being exhausted into the atmosphere by the booth exhaust fans. The function of both filter types is paramount to the spray booth functioning properly and ensuring the best possible coating finish. Spray booths are designed to meet National Standards, such as OSHA and the NFPA.
When filter maintenance is neglected, the performance of the spray booth will fall below the standards’ requirements. When the spray booth performs below the designed param¬eters, proper airflow will not be present and the likelihood of overspray or dust to accumulate on the coated part increases exponentially. Because there are many different filter constructions available, it is difficult to mandate a certain time interval for filter change outs. There are many other factors that play a part in the life span of the filters, including cleanliness of the surrounding environment, type of coating being sprayed, application styles and equipment used, spray booth air speed, spray booth design and construction and design of the filters can all affect the life of the filter. However, there are some key indicators that your filters are coming to the end of their effective life span:
Intake Filters:
• When an increase in debris or dust is noticed in the booth or in the coatings.
• If you have a manometer or Magnehelic gauge to measure pressure, drop through the filter, change at the suggested loading of the manufacturer.
• Filters have been installed for six months.
Exhaust Filters:
• When overspray is noticed to be lingering in the booth more than usual.
• The spray booth fan is operating at 100% capacity.
• If you have a manometer or Magnehelic gauge to measure pressure, drop through the filter, change at the suggested loading of the manufacturer.
• Applying a coating that is capable of spontaneous combustion or other harmful compounds.
• Filters have been installed for one month.
It is best practice to establish a filter maintenance program with the help of RTT Finishing Solutions. Improper filter maintenance can affect more than just the finished coating. It can also affect the health and safety of your employees as well as the profitability of your business.
Where Should the Temperature Sensor Be Located on My Spray Booth?
RTT recommends that the temperature probe be in the discharge ductwork of the Air Make-up Unit (AMU). The probe is to be located as far from the discharge location of the AMU as possible before entering the paint booth intake plenum. This configuration helps to avoid sharp spikes in temperature and will even out the ramp and soak time of the burner. Eliminating the possibility of an over-temperature situation inside the AMU. In rare instances, the temperature probe may be in the intake plenum of the spray booth. Please consult with RTT Technical Support before locating the temperature probe anywhere other than the AMU discharge ductwork.
Why Are My Spray Booth Doors Being Blown Open?
This is typically caused by excessive incoming gas pressure affecting system balance. When gas pressure exceeds regulator ratings:
• Airflow and burner output become unstable
• The system may create positive pressure inside the booth
• Doors can blow open due to improper pressure differential
Check the valve train regulator, system gas pressure, and follow the manufacturer’s recommended pressure ranges.
My Spray Booth and Oven Controls Require a Password to Change Settings - What Is It?
CT/CTC AMU – All passcodes provided in the RTT Booth & AMU Detailed Start-up Guide).
Operator passcode is 2050
Oven – All passcodes in the Oven Operation & Maintenance manual. Maintenance passcode is 1111
My Exhaust Fan Is Not Running Even Though My Booth Has Power — What Could Be Causing It?
There could be several issues that could cause your exhaust fan not to operate. If you have confirmed you have power, do you have a fault on your Variable Frequency Drive (VFD)? Check to see if there is a fault code displayed on the VFD. Depending on the make and model of your VFD these codes can differ.
Related Products
Finishing Prep Station
- Preparation Equipment
Automotive Paint Mixing Room
- Preparation Equipment
Industrial Paint Mixing Room
- Preparation Equipment
EZ Modified Downdraft
- Automotive Paint Booths
EZ Side Downdraft
- Automotive Paint Booths
EZ Pit Downdraft
- Automotive Paint Booths
